2,043 research outputs found

    Pulmonary Embolism Incidence and Fatality Trends in Chinese Hospitals from 1997 to 2008: A Multicenter Registration Study

    Get PDF
    BACKGROUND: There has not been sufficient evidence to support the Asians being less susceptible to pulmonary embolism (PE) than other ethnicities, because the prevalence of PE/deep venous thrombosis (DVT) in different racial and ethnic groups has not been carefully studied until recently except in Caucasians. To test the hypothesis that the Chinese population has a lower risk for PE, this study comprehensively assessed the hospital-based incidence and case fatality rates for PE during the 1997-2008 in China. METHODS: A registration study of patients with suspected PE syndromes admitted to 60 level-3 hospitals involved in the National Cooperative Project for the Prevention and Treatment of Venous Thromboembolism (NCPPT) was conducted from January 1997 to December 2008. The only exclusion criterion was an age of less than 18 years. Helical computed tomography scan, ventilation-perfusion lung scintigraphy or pulmonary angiography was carried out before or after hospitalization. All images were reviewed and evaluated independently by two specialists. RESULTS: A total of 18,206 patients were confirmed with PE from 16,972,182 hospital admissions. The annual incidence was 0.1% (95% CI: 0.1% to 0.2%). The overall incidence of PE in male patients (0.2%, 95% CI: 0.1% to 0.3%) was higher than that in female patients (0.1% and 95% CI: 0.0% to 0.1%). An increasing incidence gradient for PE was noticed from Southern to Northern China. In addition, the case fatality rate was apparently decreasing: 25.1% (95% CI: 16.2% to 36.9%) in 1997 to 8.7% (95% CI: 3.5% to 15.8%) in 2008. CONCLUSIONS: Our findings suggest the relatively stable PE incidence and decreasing fatality trends in Chinese hospitals may be partially attributable to the implementation of the NCCPT and suggest the government should reevaluate the severity of PE so that health resources for the prevention, diagnosis and treatment of PE could be used to their fullest

    Frustration and thermalization in an artificial magnetic quasicrystal

    Get PDF
    Artificial frustrated systems offer a playground to study the emergent properties of interacting systems. Most work to date has been on spatially periodic systems, known as artificial spin ices when the interacting elements are magnetic. Here we have studied artificial magnetic quasicrystals based on quasiperiodic Penrose tiling patterns of interacting nanomagnets. We construct a low-energy configuration from a step-by-step approach that we propose as a ground state. Topologically induced emergent frustration means that this configuration cannot be constructed from vertices in their ground states. It has two parts, a quasi-one-dimensional ‘skeleton’ that spans the entire pattern and is capable of long-range order, surrounding ‘flippable’ clusters of macrospins that lead to macroscopic degeneracy. Magnetic force microscopy imaging of Penrose tiling arrays revealed superdomains that are larger for more strongly coupled arrays, especially after annealing the array above its blocking temperature

    Pulmonary embolism and patent foramen ovale thrombosis: the key role of TEE

    Get PDF
    This is a case report of a 35 young man with Klinefelter Syndrome presented breathlessness, palpitations and chest pain. It shows a rare case of a thrombus located through the PFO, in patient with pulmonary and paradoxical embolism, which takes back to exciting hypothesis on thrombus growth. A thrombus, which has grown 'in situ' or trapped through the patent foramen ovale, may be a cause of relapsing pulmonary or systemic embolism during anticoagulation therapy

    Electrothermal Icing Protection of Aerosurfaces Using Conductive Polymer Nanocomposites

    Get PDF
    Ice protection systems (IPS) are critical components for many aerospace flight vehicles, including commercial transports and unmanned aerial systems (UAS), and can include anti-icing, de-icing, ice sensing, etc. Here, an IPS is created using nanomaterials to create a surface-modified external layer on an aerosurface based on observations that polymer nanocomposites have tailorable and attractive heating properties. The IPS uses Joule heating of aligned carbon nanotube (CNT) arrays to create highly efficient de-icing and anti-icing of aerosurfaces. An ice wind tunnel test of a CNT enhanced aerosurface is performed to demonstrate the system under a range of operating regimes (temperature, wind speed, water content in air) including operation down to -20.6°C (-5°F) at 55.9 m/s (125 mph) under heavy icing. Manufacturing, design considerations, and further improvements to the materials and systems are discussed.United States. Dept. of the Navy. Small Business Innovation Research (Contract N68335-11-C-0424)National Science Foundation (U.S.). Materials Research Science and Engineering Centers (Program) (Grant DMR-0819762

    Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report

    Get PDF
    Occurrence of bioprosthetic valve thrombosis less than a year after replacement is very uncommon. Here, we describe a case of a 57 year old male, who presented 10 months after receiving a bioprosthetic mitral valve replacement with a two week history of dyspnea on exertion, worsening orthopnea and decreased exercise tolerance. Echocardiography revealed severe mitral regurgitation (MR), thrombosis of the posterior mitral leaflet, left atrial (LA) mural thrombus and a depressed left ventricular ejection fraction of twenty-five percent. Given severe clot burden and decompensated heart failure (New York Heart Association - NYHA class III) repeat sternotomy was done to replace the bioprosthetic mitral valve and remove LA mural thrombus. MR was resolved postoperatively. This brief report further reviews promoting factors, established guidelines and management strategies of bioprosthetic valve thrombosis

    The Barcode of Life Data Portal: Bridging the Biodiversity Informatics Divide for DNA Barcoding

    Get PDF
    With the volume of molecular sequence data that is systematically being generated globally, there is a need for centralized resources for data exploration and analytics. DNA Barcode initiatives are on track to generate a compendium of molecular sequence–based signatures for identifying animals and plants. To date, the range of available data exploration and analytic tools to explore these data have only been available in a boutique form—often representing a frustrating hurdle for many researchers that may not necessarily have resources to install or implement algorithms described by the analytic community. The Barcode of Life Data Portal (BDP) is a first step towards integrating the latest biodiversity informatics innovations with molecular sequence data from DNA barcoding. Through establishment of community driven standards, based on discussion with the Data Analysis Working Group (DAWG) of the Consortium for the Barcode of Life (CBOL), the BDP provides an infrastructure for incorporation of existing and next-generation DNA barcode analytic applications in an open forum

    Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry: The EFFORTLESS Study.

    Get PDF
    BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to defibrillate ventricular arrhythmias, avoiding drawbacks of transvenous leads. The global EFFORTLESS S-ICD (Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD) registry is collecting outcomes in 985 patients during a 5-year follow-up. OBJECTIVES: The primary goal of the EFFORTLESS registry is to determine the safety of the S-ICD by evaluating complications and inappropriate shock rate. METHODS: This is the first report on the full patient cohort and study endpoints with follow-up ≥1 year. The predefined endpoints are 30- and 360-day complications, and shocks for atrial fibrillation or supraventricular tachycardia. RESULTS: Patients were followed for 3.1 ± 1.5 years and 82 completed the study protocol 5-year visit. Average age was 48 years, 28% were women, ejection fraction was 43 ± 18%, and 65% had a primary prevention indication. The S-ICD system and procedure complication rate was 4.1% at 30 days and 8.4% at 360 days. The 1-year complication rate trended toward improvement from the first to last quartile of enrollment (11.3% [quartile 1]) to 7.8% [quartile 2], 6.6% [quartile 3], and 7.4% [quartile 4]; quartile 1 vs. quartiles 2 to 4; p = 0.06). Few device extractions occurred due to need for antitachycardia (n = 5), or biventricular (n = 4) or bradycardia pacing (n = 1). Inappropriate shocks occurred in 8.1% at 1 year and 11.7% after 3.1 years. At implant, 99.5% of patients had a successful conversion of induced ventricular tachycardia or ventricular fibrillation. The 1- and 5-year rates of appropriate shock were 5.8% and 13.5%, respectively. Conversion success for discrete spontaneous episodes was 97.4% overall. CONCLUSIONS: This registry demonstrates that the S-ICD fulfills predefined endpoints for safety and efficacy. Midterm performance rates on complications, inappropriate shocks, and conversion efficacy were comparable to rates observed in transvenous implantable cardioverter-defibrillator studies. (Evaluation oF Factors ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD [The EFFORTLESS S-ICD Registry]; NCT01085435)

    MRI of the lung (3/3)-current applications and future perspectives

    Get PDF
    BACKGROUND: MRI of the lung is recommended in a number of clinical indications. Having a non-radiation alternative is particularly attractive in children and young subjects, or pregnant women. METHODS: Provided there is sufficient expertise, magnetic resonance imaging (MRI) may be considered as the preferential modality in specific clinical conditions such as cystic fibrosis and acute pulmonary embolism, since additional functional information on respiratory mechanics and regional lung perfusion is provided. In other cases, such as tumours and pneumonia in children, lung MRI may be considered an alternative or adjunct to other modalities with at least similar diagnostic value. RESULTS: In interstitial lung disease, the clinical utility of MRI remains to be proven, but it could provide additional information that will be beneficial in research, or at some stage in clinical practice. Customised protocols for chest imaging combine fast breath-hold acquisitions from a "buffet" of sequences. Having introduced details of imaging protocols in previous articles, the aim of this manuscript is to discuss the advantages and limitations of lung MRI in current clinical practice. CONCLUSION: New developments and future perspectives such as motion-compensated imaging with self-navigated sequences or fast Fourier decomposition MRI for non-contrast enhanced ventilation- and perfusion-weighted imaging of the lung are discussed. Main Messages • MRI evolves as a third lung imaging modality, combining morphological and functional information. • It may be considered first choice in cystic fibrosis and pulmonary embolism of young and pregnant patients. • In other cases (tumours, pneumonia in children), it is an alternative or adjunct to X-ray and CT. • In interstitial lung disease, it serves for research, but the clinical value remains to be proven. • New users are advised to make themselves familiar with the particular advantages and limitations

    Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial

    Get PDF
    BACKGROUND: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. METHODS: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. RESULTS: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. CONCLUSIONS: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379
    corecore